bidones-tecnocoat

TECNOCOAT H-2049

Polyurea membrane for waterproofing and coating

Two- component, hot-spray polyurea membrane for waterproofing, protection and sealing. It is made up of two highly reactive liquid components, Tecnocoat P-2049 /A (isocyanates) and Tecnocoat H-2049/B (resins), mixed together using our specific spray equipment TC2049 or similar, to form a solid pure and aromatic pure polyurea membrane, completely adhered to the substrate, without joints or overlaps, elongable, watertight and waterproof, with high mechanical properties and shore hardness.



0 emisiones VOC

Uses

For application in the following situations:

  • Sloped/flat walkable roofs, IRMA, balconies, and overhangs (ETA 20/0263)
  • Green roofs (P4:TH4, ETA 20/0263)
  • Retaining walls and foundations, Concrete decks (EN 1504-2)
  • Swimming pools and water parks
  • Vehicle and boat coatings(bed liners)
  • Furniture and thematizations
  • Flat or sloped asbestos roofs (on TECNOFOAM, spray polyurethane foam system)
  • As a protection for SPF (TECNOFOAM, spray polyurethane foam system)

NOTE: call our technical department about the application to other substrates or scopes of use

minimum thickness ±1.5 mm.
tack-free time ±5 secs
tensile strength >19 MPa
elongation at  break  >390 %
shore Hardness A/D  >90 / >45
application method spray equipment


TDS. Technical Data sheet(PDF)
MSDS, CERTIFICATES, APPROVALS...(link)
CE Marking - Declaration of Performance (DoP)

Declaración de prestaciones

PRODUCTSTANDARDDATEREVISIONLINK
TECNOCOAT H-2049 1504 2023-03-23 2 DOWNLOAD
TECNOCOAT H-2049 1504 2021-05-25 1 DOWNLOAD
TECNOCOAT H-2049 1504 2020-03-26 0 DOWNLOAD
TECNOCOAT H-2049 EAD030350-00-0402 2023-03-23 1 DOWNLOAD
TECNOCOAT H-2049 EAD030350-00-0402 2021-07-14 0 DOWNLOAD

GENERAL SPECIFICATIONS

  • Two-component, 100% solids content, aromatic polyurea that once applied, forms a hard-wearing, continuous, seamless, waterproofing, and solid membrane that offers a certified waterproofing, watertight behavior.
  • It holds an ETA 20/0263, issued by EOTA (European Organization for Technical Assessment). under the EAD 030350-00-0402 guide, specific approval for "Liquid Applied Roof Waterproofing Kit, based on pure polyurea" working life 25 years ( W3), at 1.4 mm thickness, ponding water admitted
  • Green roof application certified, root resistance,according to the EN 13948 (ETA 20/0263)
  • It has CE marking on the basis of a statement made DoP Declaration of Performance (DoP) conforms to the regulations UE 305/2011
  • The application and training are done by our spray equipment TC2049 (spray-equipment.tecnopolgroup.com) or similar
  • Thanks to its versatility and its tack-free time of around 3-5 seconds, allows the adherence to any surface, making it the ideal product for application on uneven surfaces and in areas of any shape, whether curved or squared.
  • Due to its resistance, it can be walked on and it will accept a rough finish to make it non-slip. (using Silica Sand or Tecnoplastic range aggregates)
  • A ceramic floor can be placed on top. In this case, we recommend applying a thin coat of Primer PU-1000 or Primer PU-1050, consumption of around 50 to 60 g/sqm, and spreading Silica Sand on top, consumption of around 700-1000 g /sqm, to improve mechanical anchorage.
  • Joints and any type of union are saved since the finish is uniform and in one piece, providing a surface with optimal maintenance and cleaning.
  • Has properties to allow it to adhere to most surfaces such as concrete, ceramic tiles, metals, spray polyurethane foam (Tecnofoam), plywood(OSB), asphalt/bituminous sheets. In any case or material, the surface must be consistent and sound (concrete pull-off strength >1.5 MPa), clean, and dry when the products are applied. Recommended applying directly on the concrete deck.
  • Free from harmful VOC compounds, therefore, it does not hurt the ozone layer (VOC's zero). It's 100% recyclable by mechanical means friendly to the environment; no gas collection for recycling and/or destruction is required; it doesn´t emit substance to the environment once installed.
  • It should be applied in dry conditions avoiding the presence of humidity or coming from the surface to be coated or the substrate, whether at the time of application or subsequently (pressure from phreatic water level). In the event there is humidity in the substrate at the time of application.
  • It is an aromatic membrane and, even though it is stable against solar radiation it requires solar radiation protection (UV rays) to do not lose its physical and mechanical properties. Therefore, our approved system (under ETA 20/0263), incorporates a protective polyurethane colored aliphatic resin, Tecnotop 2C, for use in the absence of other physical protection elements. You can apply  Tecnotop S-3000, Tecnotop 2CP or Tecnotop 1C also.

YIELD

The recommended minimum thickness is 1.5 mm. (60 mils DFT), total yiedl is 1.7 kg/sqm, applied in various coats. The total thickness may vary according to support or climatological conditions.

PACKAGING

Metallic drum kit, in two different formats:

  • LARGE KIT: 225 kg each component (B side: resin and A side: isocyanates).
  • SMALL KIT: 60 kg each component (B side: resin and A side: isocyanates).

SHELF LIFE

12 months at temperatures between 5 and 35° C (41 to 95 ºF), provided it is stored in a dry place. Once the tin has been opened, the product must be used. B side must be agitated mechanically before inserting the transfer pumps and use.

Concrete substrate

  • concrete should be completely cured (concrete curing takes 28 days) or, in any case, the maximum level of humidity allowed for the substrate should be verified, depending on the primer used.
  • concrete must have a surface with a correct planimetry, high surface resistance, eliminating laitance or release agents, without excessive irregularities. Therefore, the previous action of sanding, polishing, milling or shot-blasting will be assessed by the applicator to achieve a preparation of the support according to ICRI Guide 03732, CSP values 3 to 5.
  • cracks and damaged areas must be repaired using epoxy mortar Primer EP-1020/Primer EP-1010.
  • Mastic PU must be used on fissures or small cracks on the surface.
  • In joints (width < 15 mm): remove old material, clean and fill with Mastic PU.
  • In joints (width >15 mm): remove old material, clean and fill with Mastic PU. Complement with a Tecnoband 100 band on the upper part.
  • in structural/expansion joints: remove old material, clean and fill with Mastic PU. Complement with specific elastic bands and Tecnoband 100
  • clean up well and eliminate all contaminants from the elements, such as dust or chippings, using dry methods preferably.
  • primer application using our Primer PU-1050/Primer PUc-1050, total yield of 250 g/sqm (applied in several thin coats) or Primer WET depending on the existing moisture in the substrate and with a total yield of 450 g/sqm
  • apply/spray the membrane evenly and in several layers until the dry film thickness required by the project is achieved.
  • application of the aliphatic polyurethane resin for protection against UV rays Tecnotop 2C/2CP/1C

Ceramic tiles substrate

  • ceramic surfaces should not have empty joints or loose elements or parts. These should be filled with Mastic PU mastic or mortar, according to their size.
  • existing joints or seals: remove the old material, clean up and fill with Mastic PU and reinforced using Tecnomesh 100
  • sanding with specific equipment. Thereby, to remove moss or solids particles bonded to the support, and opening the pore.
  • clean up, using a vacuum method.
  • primer application using Primer EP-1040, total yield 100-150 g/sqm, or Primer EPw-1070, total yield 150-200 g/sqm
  • apply/spray the membrane evenly and in several layers until the dry film thickness required by the project is achieved.
  • application of the aliphatic polyurethane resin for protection against UV rays Tecnotop 2C/2CP/1C.

NOTE: For other types of supports, weather conditions or the substrate to be applied, consult our technical department.

REPAIR AND OVERLAPS PROCESSES

REPAIR
In cases where the membrane repair by accidental causes, or assembly procedures not covered installations, shall be as follows:

  • cut, removal of the affected area and/or damaged surface
  • sanding this area extending about 20~30 cm. around the perimeter, for overlapping security
  • cleaning (vacuuming) of waste generated (powder, dust...); if it's possible don't use water, and if used, support humidity value; ketones applicability based solvents for reducing this type of surface cleaning
  • apply a thin layer (100-150 g/sqm) of polyurethane resin Primer PU-1030, Primer PU-1050, Primer PU-1000.
  • light spread Silica Sand over the wet primer applied before
  • wait for the total drying
  • apply/spray the membrane evenly and in several layers until the dry film thickness required by the project is achieved.
  • application of the aliphatic polyurethane resin for protection against UV rays Tecnotop 2C/2CP/1C

OVERLAPS
In cases has been exceeded recoat time (24~48 hours), so the waiting time between jobs is prolonged, proceed as follows:

  • sanding strip longitudinal overlap of about 20~30 cm. wide
  • cleaning (vacuuming) of waste generated (powder, dust...)or existing dust; if it's possible, do not use water, and if it's used, check the support humidity value; ketones applicability based solvents for conducting this type of surface cleaning
  • apply a thin layer (100-150 g/sqm) of polyurethane resin Primer PU-1030, Primer PU-1050, Primer PU-1000.
  • light spread Silica Sand over the wet primer applied before
  • wait for the total drying
  • apply/spray the membrane evenly and in several layers until the dry film thickness required by the project is achieved.
  • application of the aliphatic polyurethane resin for protection against UV rays Tecnotop 2C/2CP/1C

APPLICATION REQUIREMENTS (spray equipment)

For the formation, it is necessary to mix the two initial liquid components, isocyanates and resin by our spray equipment TC2049 (spray-equipment.tecnopolgroup.com) or similar (proper maintenance and cleaning it is recommended). The general parameters for this material will be the following:

  • Isocyanate heater temperature: 70-75 ºC (158 to 167ºF)
  • Resine heater temperature:70-75ºC   (158 to 167ºF)
  • Hose temperature:±70 ºC (158ºF )
  • Working pressure: 2.500 - 3.000 psi (170 to 205 bar)
  • Recommended mixing chamber: GU-07008-1 or GU-07008-2 (use mechanical purge chamber)

These temperatures and pressure parameters must be valued, ratified or slightly varied by the applicator, depending on the conditions of each climatic zone, weather situation or according to the specifications of the projection equipment. It is the responsibility of the owner / applicator of the equipment to keep it in perfect condition in order to maintain the correct mixing ratio of the two components that Tecnopol delivers separately, by periodically updating its maintenance controls. During the execution of the application, it may be necessary to correct these parameters according to changing external conditions, as well as to verify the correct operation of the machine (pressure and temperature).

HEALTH AND SAFETY

These safety recommendations for handling, are necessary for the implementation process as well as in the pre and post, on exposure to the loading machinery.

  • Respiratory Protection: When handling or spraying use an air-purifying respirator.
  • Skin protection: Use rubber gloves, remove immediately after contamination. Wear clean body-covering. Wash thoroughly with soap and water after work and before eating, drinking, or smoking.
  • Eye / Face: Wear safety goggles to prevent splashing and exposure to particles in the air.
  • Waste: Waste generation should be avoided or minimized.
  • Incinerate under controlled conditions in accordance with local laws and national regulations.
  • Re-occupancy of the work site without respiratory equipment is minimum 24 hours providing the correct ventilation for the area sprayed.
  • Contractors and applicators must comply with all applicable and appropriate guidelines for storage and safety guidelines.

Consult the material and safety data sheet of the products of the system.

TECHNICAL AND CHEMICAL PROPERTIES (ACCORDING TO ETA 20/0263)

PROPERTIES

RESULTS

Density   ISO 1675

±1.10 ±0.02 g/cm³

Density compounds* A/B  ISO 1675 1.11±0.03 g/cm³  /  1.09±0.03 g/cm³
Viscosity compunds* A/B (at 12 rpm)   ISO 2555 850±50 cps  /  1,500±400 cps
Mixing ratio (weight/volume) 100/102 - 100/100
Tack-free time ±5-7 secs
Recoat time 10 secs ~ 48 hours   
Use temperature range (environment) -10 ~ 90 ºC      (14 to 194ºF)
Application temperature range (substrate  and environment) 5~ 35 ºC   (41 to 95ºF)
Maximum environmental humidity ±80%

Elongation at break       ISO 527-3

>390%

Tensile Strength     ISO 527-3

>19 MPa

Hardness Shore A/D        DIN 53.505

>90 / >45

Solid content      ISO 1768 100%
VOC content (volatile organic compounds) 0
Working life W3:25 years (minimum thickness 1.4 mm.)
Climatic zone S (hard weather)
Resistance to water vapor diffusion   EN 1931 µ=1,700
Water vapor diffusion   ISO 7783 0.045 g/ sqm/day
Temperatures / User loads

P3:TH4-TH1, for XPS /  P4:TH4-TH1, for concrete and steel

Construction element slope S1~S4, zero slope, ponding water admitted
Fire reaction   EN-ISO 13501-1:2019 Euroclass E
Adhesion to concrete/Steel/XPS 3,000 kPa/3,600 kPa/86 kPa
Hail impact test      TUVRheinland pass at 1.5 mm. on aluminum / glass-fiber substrates
Depth of water penetration at 10 bar     DIN 1048 Pt 5 0 mm 
Anti roots certificate    EN 13948:2008 PASS

Results were performed in the laboratory at 25ºC  (73ºF) and 50% RH, under controllable conditions. These values may vary depending on the application, climatology, or substrate conditions.

* Data for component B pigmented in gray. For other colorations or neutral, consult the official COA issued by Tecnopol (Certificate of Analysis for each batch delivered). Results performed in the laboratory at 23ºC and 50% RH, under controllable conditions.


ASTM

PROPERTIES

RESULT

Tensile strength           ASTM D412:2016 (Method A) 20.48 MPa ( 2,970 psi)
Elongation at break     ASTM D412:2016 (Method A) 605 %
Hardness Shore A/D     ASTM D2240:2015 97 /  52
Tear strength     ASTM 624-00:2012 101.6 N/mm
Water vapor transmission     ASTM E96/E96M-16 0.19 g/sqm/day
Adhesion strength to steel    ASTM D4541 3.23 MPa (468 psi)
Taber abrasion (H18 wheel, wear index / H22 wheel, wear index)       ASTM D4060:2014 152 mg / 113 mg
Water absorption       ASTM D570-98:2018 0%
Impact resistance        ASTM G14-04:2010 e1 55.68 kg.cm
UV accelerated weathering (1000hours)        ASTM G154-16 no blistering/no cracking/no chalking/no peeling/no delamination
Crack Bridging          ASTM C1305/C1305M-16 and ADM/CE/002:2017

no cracks occurred after 10 cycles at 8 mm. /  crack at 12 mm width